ASTM D5588-1997 Standard Test Method for Determination of Microbial Conditions in Paints, Paint Raw Materials, and Plant Areas

Bedeutung und Verwendung

3.1 Spoilage of paint in containers is usually associated with the use of contaminated raw materials, Wasser (especially recycled washing water), containers, pipes and equipment in manufacturing plants. A simple method is needed to determine the presence or absence of microorganisms in plants that make paints and coatings. Such determination allows manufacturers to identify contamination points (d.h., raw materials or problem management areas in the plant) to help address corruption.

Notiz 1: Some contamination of plant areas is expected, as microorganisms are ubiquitous and in practice usually cannot be eliminated (this is what the preservatives in the tank should control). Excessive contamination or contamination of raw materials may exceed the capacity of the preservative. If your plant has excessive contamination, there are disinfection methods including steam, preservatives, bleichen, usw. These should be discussed with your fungicide supplier and used with care. Recycling spoiled or contaminated products is often not feasible, so the importance of proper fungicide levels combined with good plant management practices is self-evident. Your biocide supplier can also help here.

3.2 This test method can be used by people without basic microbiological training, but some training in aseptic techniques is recommended.

Notiz 2: The reliability of the results obtained from this test method depends greatly on the technique used. Incorrect techniques can result in sterile samples being contaminated, or worse, contaminated samples appearing sterile (sehen 5.1). It is recommended that you consult your biocide supplier, raw material supplier or independent testing laboratory to confirm suspicious results.

ASTM D5588-1997 Standard Test Method for Determination of Microbial Conditions in Paints, Paint Raw Materials, and Plant Areas

Schritt 1: Umfang

1.1 This test method includes procedures for determining the microbial status (contaminated or sterile) of raw materials used in paint production and the microbial status of paint and paint manufacturing areas.

1.2 In SI-Einheiten ausgedrückte Werte gelten als Standard. Die in Klammern angegebenen Werte dienen nur als Referenz.

1.3 Diese Norm soll nicht alle Sicherheitsbedenken berücksichtigen, wenn überhaupt, mit seiner Verwendung verbunden. Es liegt in der Verantwortung der Benutzer dieser Norm, vor der Verwendung geeignete Sicherheits- und Gesundheitspraktiken festzulegen und die Anwendbarkeit behördlicher Beschränkungen zu bestimmen.

1.4 Dieser internationale Standard basiert auf international anerkannten Standardisierungsprinzipien, die in der EU festgelegt wurden “Entscheidung über Grundsätze für die Entwicklung internationaler Standards, Richtlinien und Empfehlungen” herausgegeben vom Ausschuss für technische Handelshemmnisse (TBT) der Welthandelsorganisation.

Teile diesen Beitrag