תיאור

E40 7006-53-1 Anti-accidental electric shock gauge

E40 lamp holder and holder gauge technical standard: GB 1483.1-2008; חברת החשמל 60061-3:2004

Gauge for inspecting finished lamps with E40 caps against accidental contact


The plunger of the gauge is shown in the test position. When the plunger is at rest, surface W shall be retracted deeper than surface V.

Referenceמֵמַד(מ"מ)סוֹבלָנוּת(מ"מ)Referenceמֵמַדסוֹבלָנוּת
ד39.6+0.0/-0.02פ21±0.1
ו40.2+0.05/-0.0ש32±0.1
G44+0.05/-0.0רApprox.25
ח22±0.1U12±0.1
M50.4±0.1ר4.5+0.5/-0.0
נ51.4+0.0/-0.02α35°±30

E40 7006-53-1 Anti-accidental electric shock gauge

מַטָרָה:

To check protection against accidental contact during insertion of caps E27 on finished lamps.

E40 7006-53-1 Anti-accidental electric shock gauge
Testing :

The shape of the lamp with regard to protection against accidental contact is assumed to be correct if, when the lamp is pushed as far as possible into the gauge, surface W does not protrude beyond surface V.

E40 7006-53-1 Anti-accidental electric shock gauge
מַטָרָה:

To check protection against accidental contact during insertion of caps E27 on finished lamps.

E40 7006-53-1 Anti-accidental electric shock gauge
Testing :

The shape of the lamp with regard to protection against accidental contact is assumed to be correct if, when the lamp is pushed as far as possible into the gauge, surface W does not protrude beyond surface V.






    התווסף לעגלת הקניות שלך:
    לבדוק