Characteristics of network return control gas chromatograph:

  • Using the advanced 10/100m adaptive Ethernet communication interface and built-in IP protocol stack, the instrument can easily realize long-distance data transmission through Intranet and Internet of enterprises;It facilitates the erection of laboratory and simplifies the laboratory configuration and data management.
  • Low instrument internal design process of three separate connection, can connect to the local processing, unit director and supervisor, you can easily make unit director and supervisor real-time monitoring instrument is running and analysis data;
  • Low instrument equipped with built-in integration design return control chromatography workstation, get rid of the traditional data acquisition card processing, поддержка до 253 sets of chromatographic work at the same time, data processing and the chromatograph, reached the domestic leading level;
  • The Modbus/TCP server built in the built-in integrated return control workstation can easily connect the analysis results to the DCS (распределенная система управления), and all parameters of the real-time return control chromatograph;
  • The instrument adopts vacuum fluorescence display technology, высокий – end atmosphere and convenient interface operation.Have two operating languages in English and Chinese to meet different user needs;
  • The instrument adopts the modular structure design, the design is clear, the replacement upgrade is convenient, protects the effectiveness of the investment;It can satisfy complex sample analysis, and it can be selected with many high performance detectors, такие как ФИД, ТЦД, РДРВ, ФПД и НДП.
  • Can realize completely abandoned the traditional mechanical valve, pointer type pressure gauge mode!EPC technology is used to control gas path and improve the automation level of gas chromatography.
  • The real gas road failure automatic protection, обнаружение давления, расхода, автоматическое зажигание, automatic fire extinguishing automatic key, automatic gas path opening, reached a key start;
  • When the instrument is designed, it can easily complete the online analysis of the gas and liquid sample (with the sample parts).
  • The system is designed for automatic sampler interface, convenient for automatic sampler and future upgrade.

Основная спецификация

Operation display: вакуумный флуоресцентный дисплей (using agilent technology)

Temperature control area: 6

Low operating temperature: комнатная температура 4 ℃ ~ 450 ℃, the incremental: 1 ℃, точность: plus or minus 0.1 ℃

Program heating order number: 8-16 (необязательный)

Low Cheng Sheng rate: 0.1 ~ 50 ℃ / мин (обычный);0.1 ~ 80 ℃ / мин (высокоскоростной)

External events: 8 roads;Вспомогательный выход управления 4

Type of sample: filling column, capillary injection sample, шестиходовой клапан впрыска газа, automatic head space sampling

Number of detectors: 3 (максимум);(ПИД, ТЦД, РДРВ, ФПД, НДП)

(1) it can be controlled by high-precision valve, and the pressure, real-time digital display of the flow and the PC synchronization display are realized.(2) an EPC control system with full back control;

Work mode of EPC and EFC: 2 types;Режим постоянного тока, constant pressure mode

Work gas of EPC and EFC: 5 types;Азот, водород, воздух, гелий, аргон

EPC, EFC cheng sheng: 4

The control range of EPC and EFC:

Давление: 0 ~ 0.6mpa;Поток 0 ~ 100сксм или 0 ~ 500сксм (воздух)

Control accuracy of EPC and EFC: давление 0.01 кПа;The flow rate of 0.01 SCCM

Low pressure sensor: точность: full range of plus or minus 2% reproducibility: < + / – 0.05 KPa temperature coefficient: < + / – 0.01 кПа / ° C range: 0 ~ 0.3 MPa or 0 ~ 0.6 МПа;

Flow sensor: точность: full range of < 5% reproducibility: < + 0.5% (полный диапазон) диапазон: 0 ~ 500сксм

(руководство, автоматический, needle automatic detection) необязательный

Интерфейс связи: Ethernet: IEEE802.3 водородный пламенно-ионизационный детектор (ПИД)

Предел обнаружения: Mt is less than 3 x 10-12g/s (positive hexadecaneisooctane solution);

Базовый шум: меньше, чем 5 x 10-14a

Baseline drift: не более чем 1 x 10-13a /30min

Линейный диапазон: больше чем 106

Highest use low temperature: 450 ℃ or less thermal conductivity detector (ТЦД)

The sensitivity: S is greater than 10000mV. Ml/mg (positive hexadecaneisooctane solution) (amplification 1, 2, 4, 8 times optional)

Базовый шум: меньше, чем 10 mu V

Baseline drift: не более чем 30 mu v/30min

Линейный диапазон: > 104 electronic capture detector (РДРВ)

Предел обнаружения: не более чем 1 x 10-14g/s (propane hexa6-isooctane solution)

Базовый шум: less than 0.03mV

Baseline drift: no more than 0.2mv /30min

Линейный диапазон: greater than or equal to 104

Источник: 63Ni flame photometric detector (ФПД)

Предел обнаружения: (С) меньше, чем 5 Икс 10-11 g/S;(п) is less than or equal to 1 x 10-12g/s (метилпаратион – anhydrous ethanol solution)

Базовый шум: less than 0.03mV

Baseline drift: no more than 0.2mv /30min

Линейный диапазон: equal to 103 (С) 102 (п) nitrogen and phosphorus detector (НДП)

The detection limit: (Н) is less than or equal to 1 times 10-13g/s;(п) меньше, чем 5 x 10-14g/s (azobenz-malathionisooctane solution)

Базовый шум: less than 0.03mV

Baseline drift: no more than 0.2mv /30min

Линейный диапазон: greater than or equal to 102 (Н) 103 (п)

 

 