Programmable Comprehensive Electrical Safety Tester Hipot Insulation Ground Leakage Current Power Testing Machine Electrical Safety Compliance Test Instrument
- Description
- Inquiry
Description
Programmable Comprehensive Electrical Safety Tester Hipot Insulation Ground Leakage Current Power Testing Machine Electrical Safety Compliance Test Instrument
Product Features
- It integrates AC/DC withstand voltage, insulation, grounding, leakage, and power tests, featuring fast testing speed and high efficiency.
- It uses a 5.6-inch TFT (640*480) display to set parameters and test parameters, with clear and rich display content.
- The tester can store test results in the form of an EXCEL table on a USB drive.
- Software upgrades can be performed via the USB drive.
- It adopts DDS digital signal synthesis technology to generate precise, stable, pure, and low-distortion sine waves.
- It allows adjustment of the rise and fall times of high voltage, enabling it to meet the requirements of different test objects.
- Two specific arc detection methods can be selected: current method and level method.
- Test results can be saved synchronously and support detailed and complete statistical operations.
- It supports online editing of test conditions by customers, facilitating intelligent and refined management.
- It has dual-frequency comprehensive testing, with a frequency range of 50 Hz and 60 Hz.
- It has an intuitive operation interface, supporting direct input with digital keys, dial input, and making operation more convenient.
- It has complete operation help prompts, which can effectively improve user efficiency.
- It has a bilingual operation interface, suitable for different user needs.
- It supports barcode scanner function.
- It comes with a PLC interface, RS232 interface, and optional LAN interface, RS485 interface, and USB interface.
Programmable Comprehensive Electrical Safety Tester Hipot Insulation Ground Leakage Current Power Testing Machine Electrical Safety Compliance Test Instrument
Technical Specification
| Model | LR-CS9940 |
| Test Modes | AC Withstand / DC Withstand / Insulation Resistance / Ground Bond / Leakage Current / Power Test (AC/DC/IR/GR/LC/PW) |
| AC Withstand Voltage Test (5kV/20mA) | |
| Output Voltage Range | 0.250kV ~ 5.000kV |
| Voltage Accuracy | ±(2% reading + 5V) |
| Voltage Resolution | 1V |
| Max Output Power | 100VA (5.000kV/20mA) |
| Max Rated Current | 20mA |
| Lower Current Limit Range | 0~20mA (0 = lower limit judgment disabled) |
| Current Ranges | 2mA, 20mA |
| Output Waveform | Pure Sine Wave |
| Waveform Distortion | ≤5% (No-load or pure resistive load) |
| Crest Factor | 1.3~1.5 |
| Signal Output Mode | Linear Power Amplifier |
| Voltage Ramp-up Time | 0, 0.3s~999.9s (0 = ramp-up function off) |
| Test Duration | 0, 0.3s~999.9s (0 = continuous testing) |
| Voltage Ramp-down Time | 0, 0.3s~999.9s (0 = ramp-down function off) |
| Interval Time | 0.0s~999.9s (0 = interval function off) |
| Arc Detection Level | 0~9 (0 = arc detection disabled) |
| DC Withstand Voltage Test (6kV/10mA) | |
| Output Voltage Range | 0.250kV ~ 6.000kV |
| Voltage Accuracy | ±(2% reading + 5V) |
| Voltage Resolution | 1V |
| Max Output Power | 60W (6.000kV/10mA) |
| Max Rated Current | 10mA |
| Lower Current Limit Range | 0~10mA (0 = lower limit judgment disabled) |
| Current Ranges | 2mA, 10mA |
| Ripple Factor | ≤5% (6kV/10mA) |
| Discharge Time | ≤200ms |
| Voltage Ramp-up Time | 0, 0.3s~999.9s (0 = ramp-up function off) |
| Test Duration | 0, 0.3s~999.9s (0 = continuous testing) |
| Voltage Ramp-down Time | 0, 0.3s~999.9s (0 = ramp-down function off) |
| Interval Time | 0.0s~999.9s (0 = interval function off) |
| Insulation Resistance Test (DC 0.5kV / 1.0kV, Max 5GΩ) | |
| Test Voltage Options | 0.500kV / 1.000kV, Resolution: 1V/Step |
| Upper Resistance Limit | 0MΩ~5000MΩ (0 = Disabled) |
| Lower Resistance Limit | 1MΩ~4999MΩ |
| Test Duration | 0, 0.3s~999.9s (0 = continuous testing) |
| Interval Time | 0.0s~999.9s (0 = interval function off) |
| Voltage Ramp-up Time | 0, 0.3s~999.9s (0 = ramp-up function off) |
| Resistance Meter Resolution & Range Accuracy | 1MΩ~9.999MΩ: 0.001MΩ
10MΩ~99.99MΩ: 0.01MΩ 100MΩ~999.9MΩ: 0.1MΩ 1000MΩ~5000MΩ: 1MΩ 1MΩ~1000MΩ: ±5% 1000MΩ~5000MΩ: ±10% |
| Ground Bond Resistance Test (32A AC, Max 150mΩ) | |
| Output Current Range | 3.0A ~ 32.0A |
| Current Accuracy | ±(2% reading + 0.1A) |
| Current Resolution | 0.1A |
| Max Output Power | 153.6VA |
| Upper Resistance Limit | Max. 510mΩ |
| Lower Resistance Limit | 0 ~ Upper Resistance Limit |
| Output Waveform | Pure Sine Wave |
| Waveform Distortion | ≤3% (No-load or pure resistive load) |
| Crest Factor | 1.3~1.5 |
| Output Drive Mode | Linear Power Amplifier |
| Current Ramp-up Time | 0, 0.3s~999.9s (0 = ramp-up function off) |
| Test Duration | 0, 0.3s~999.9s (0 = continuous testing) |
| Interval Time | 0.0s~999.9s (0 = interval function off) |
| Leakage Current Test (External Power Supply, Max 3000VA Input) | |
| Output Voltage Range | 30.0V ~ 300.0V |
| Voltage Accuracy | ±(2% reading + 1V) |
| Voltage Resolution | 0.1V |
| Current Ranges | 2mA, 20mA |
| Upper Current Limit | 0.001mA ~ 20.00mA |
| Lower Current Limit | 0 ~ Upper Current Limit |
| Human Body MD Network | Standard configuration complying with GB/T 12113 |
| Voltage Ramp-up Time | 0, 0.3s~999.9s (0 = ramp-up function off) |
| Test Duration | 0, 0.3s~999.9s (0 = continuous testing) |
| Interval Time | 0.0s~999.9s (0 = interval function off) |
| Power Load Test (External Power Supply, Max 3000VA Input) | |
| Output Voltage Range | 30.0V ~ 300.0V |
| Voltage Accuracy | ±(2% reading + 1V) |
| Voltage Resolution | 0.1V |
| Upper Current Limit | 0.100A ~ 14.00A |
| Lower Current Limit | 0 ~ 14.00A |
| Upper Power Limit | 1VA ~ 3000VA |
| Lower Power Limit | 0VA ~ 2999VA |
| Power Factor Range | 0.2 ~ 1.000 |
| Test Duration | 0, 0.3s~999.9s (0 = continuous testing) |
| Interval Time | 0.0s~999.9s (0 = interval function off) |
| Meters Parameter | |
| Withstand Voltage Meter Range | 0.250kV ~ 6.000kV, RMS display
Accuracy: ±(2% reading + 5V), Resolution: 1V |
| Withstand Current Meter | Range: 0.001mA ~ 20.00mA
Resolution: 0.001mA (2mA range), 0.01mA (10mA/20mA range) Accuracy: ±(2% reading + 5 digits) |
| Ground Bond Current Meter | Range: 3.0A ~ 32.0A, RMS display
Resolution: 0.1A, Accuracy: ±(2% reading + 2 digits) |
| Ground Resistance Meter | Range: 10.0mΩ ~ 510.0mΩ, 4-wire measurement
Resolution: 1mΩ, Accuracy: ±(2% reading + 2mΩ) |
| Leakage Current Meter | Range: 0.1μA ~ 20.00mA
Resolution: 0.001mA (2mA range), 0.01mA (20mA range) Accuracy: ±(2% reading + 5 digits) |
| Leakage & Power Voltage Meter | Range: 30.0V~300.0V, RMS display
Resolution: 0.1V, Accuracy: ±(2% reading + 1V) |
| Timer | Range: 0~999.9s, Resolution: 0.1s, Accuracy: ±(1% + 50ms) |
| Storage & Program Capacity | |
| Memory Groups | 50 sets |
| Test Steps per Group | 99 steps |
| General Machine Parameters | |
| Input Power Supply | 220V±10%, 50Hz/60Hz±5% |
| Net Weight (without package) | Approx. 22KG |
| Overall Dimension (W×H×D) | 385mm × 135mm × 455mm |
| Operating Environment | 0℃ ~ 40℃, 5%~75%RH, Low dust environment |