ASTM D7266-2013 气相色谱分析环己烷的标准测试方法 (外部标准)

意义及用途
5.1 本试验方法适用于表中所列材料的规格设定 1 and is used as an internal quality control tool for the production of cyclohexane or for manufacturing processes. It can also be used in development or research work involving cyclohexane.

5.2 This test method can be used to determine the purity of cyclohexane in the presence of normal impurities. If there are extremely high boiling points or abnormal impurities in cyclohexane, this test method will not necessarily detect them, and the purity calculation will be wrong.

ASTM D7266-2013 气相色谱分析环己烷的标准测试方法 (外部标准)

步 1: 范围

1.1 The test method includes determination of the purity of cyclohexane by gas chromatography. The calibration of gas chromatography system is completed by external standard calibration technology.

1.2 The test method has been found to be suitable for the impurities listed in Scale 1, which are impurities that may be found in cyclohexane. Impurities can be analyzed in the range of 3 to 200mg/kg by this method, but can be applied to a wider range.

1.3 The detection limit is 1 毫克/公斤.

1.4 When using this test method to determine the consistency of test results with applicable specifications, the results shall be rounded in accordance with the rounding method of Rule E29.

ASTM D7266-2013 气相色谱分析环己烷的标准测试方法 (外部标准)

1.5 以 SI 单位表示的值应视为标准值. 本标准不包含其他计量单位.

1.6 本标准并非旨在解决所有安全问题 (如果有的话) 与其使用相关. 本标准的使用者有责任建立适当的安全机制, 健康和环境实践,并在使用前确定监管限制的适用性. 参见章节 8 对于具体的危险描述.

1.7 该国际标准基于国际公认的标准化原则 “关于国际标准制定原则的决定, 指南和建议” 由技术性贸易壁垒委员会发布 (技术性贸易壁垒) 世界贸易组织.