09Oct
09Oct
ASTM D849-2015 “Test Method for Corrosion of Copper Strip by Industrial Aromatics”
The ASTM D849 standard is suitable for the development of specifications, as an internal quality control tool, and for the development or research work of industrial aromatics and related materials. Meaning and use 5.1 This test method is intended for use in the formulation of specifications, as an internal quality control tool, and in the development or research of industrial aromatics and related materials. It also indicates the presence of certain corrosive substances that may corrode the equipment, such as acidic compounds...
09Oct
ASTM D852-2016 Standard Test Method for Freezing Point of Benzene
The ASTM D852 standard can be used to determine the purity of benzene. The closer the freezing point is to pure benzene, the purer the sample. Meaning and use 5.1 This test method can be used as a standard to determine the purity of benzene. The closer the freezing point is to pure benzene, the purer the sample. ASTM D852-2016 Standard Test Method for Freezing Point of Benzene Step 1: Scope 1.1 The test method includes determination of the freezing point of benzene. 1.2 When using...
09Oct
Dielectric constant tester product introduction
Dielectric constant tester is an instrument used to measure the dielectric loss and dielectric constant of various metal oxides, mica, glass, plastics, ceramics and other substances. In fact, the purpose of using the dielectric constant tester to measure the dielectric loss and dielectric constant of different materials is to further understand the various factors affecting the dielectric loss and dielectric constant by measuring the dielectric constant and the tangent of the dielectric loss Angle, so as to provide a basis...
09Oct
Differential scanning calorimeter dsc product introduction
Published time: 2023-08-07 Clicks: 217 Differential scanning calorimeter (dsc) is a thermal analysis method to measure the relationship between the power difference and temperature between the input sample and the reference under the programmed temperature control. It is often used to measure the melting heat, crystallinity and isothermal crystallization kinetics parameters of polymers, and to determine the glass transition temperature Tg. Polymerization, curing, crosslinking, decomposition and other reactions were studied. The reaction temperature or reaction temperature zone, reaction heat and reaction...
09Oct
The color retention of the film was measured by a color difference meter
As a key element of surface protection and beautification, the coating film not only needs to have good mechanical properties, but also must resist the infringement of external factors such as light, heat and electricity during use. Among them, color retention refers to the ability of the coating to maintain its original color under exposure to light. The detection of color retention is important for various applications, from automotive painting to architectural decoration, to ensure that the film does not...
09Oct
Resistance to yellowing of film and its determination
As the outer protective layer of various products, the coating film will be affected by a variety of factors during use, one of which is the influence of light, heat and electricity. Yellowing is a common problem in the case of oil in the film. Yellowing will not only affect the appearance of the film, but also may damage the quality of the product and market competitiveness. In order to solve this problem, we need to test the yellowing resistance...
07Oct