ASTM D1555M-2016 Standard Test Method for Calculating the Volume and Weight of Industrial Aromatics and Cyclohexanes [Metric]

ASTM D1555M is suitable for calculating the weight and volume of the product outlined in Section 1. The information provided in this method can be used to determine the amount of the above-mentioned aromatics in tanks, transport containers, etc. Meaning and use 3.1 This test method is suitable for calculating the weight and volume of the product outlined in Section 1. The information provided in this method can be used to determine the amount of the above-mentioned aromatics in tanks, transport containers,...

ASTM D2359-2018 Standard Specification for Refined Benzene-53

The ASTM D2359 standard specification includes a benzene grade called refined Benzene-53. abstraction The specification covers a benzene grade called refined benzene-53. Different tests should be performed to determine the following properties of refined benzene-53: minimum purity, maximum toluene content, maximum sulfur content, maximum thiophene content, maximum non-aromatics content, maximum nitrogen content, water content, maximum pickling color, appearance, maximum color, 1,4 dioxane content, and minimum freezing point on an anhydrous basis. This summary is a brief overview of the reference standards. It is...

ASTM D4734-2018 Standard Specification for Refined Benzene-545

The ASTM D4734 standard applies to all stated limits in this standard: In order to determine consistency with this standard, observed or calculated values should be "rounded" to "nearest unit" in the last right-handed number used when expressing the specification according to the rounding method in Practice E29. abstraction This specification covers benzene-545. The following test methods shall be used to determine the performance requirements of benzene-545: % benzene by weight; Sulfur quality; Thiophene quality; Toluene quality; % non-aromatic by...

Dielectric loss tester product introduction

Dielectric loss tester product introduction Dielectric loss tester is a device used to measure the dielectric constant and dielectric loss factor of dielectric materials. Dielectric loss tester is mainly used in various metal oxides, plates, porcelain (pottery), mica, glass, plastics and other measurements, through the instrument to measure the dielectric loss and dielectric constant of different substances, to improve the performance of materials to improve the important theoretical basis. Dielectric loss tester product introduction What are the ways to measure dielectric...

Synchronous thermal analyzer product introduction

Synchronous thermal analyzer is a thermogravimetric analyzer (TG) and differential thermal analysis (DTA) or differential scanning calorimeter (DSC) combined into one, in the same measurement using the same sample can obtain thermogravimetric and differential thermal information. Synchronous thermal analyzer is widely used in the fields of metal, plastic polymer, paint, medicine, food, chemistry, glass and other materials. Through the synchronous thermal analyzer, the physical reaction of different materials at a certain temperature is measured, the corresponding measurement spectrum is obtained,...

The technical characteristics of synchronous thermal analyzer mainly have the following aspects

Synchronous thermal analyzer is a kind of multifunctional precision instrument, which is mainly used to study the thermal properties of materials at different temperatures. This instrument combines thermal analysis and a variety of detection techniques, and can obtain the thermal properties, chemical composition and structure information of samples in the same experiment process at the same time, which has the advantages of accuracy and convenience. It has a wide range of application prospects in material research, chemical research, energy research,...

dsc differential thermal analyzer product introduction

What is a dsc differential thermal Analyzer? It is a thermal analysis instrument, mainly used to measure the change of heat flow in the process of heating or cooling, by measuring the heat difference between the sample and the reference substance to determine the phase transition temperature, thermal stability and thermal decomposition kinetics of the sample. What can a dsc differential thermal analyzer measure? It mainly studies the phase transformation of materials, melting, transformation of crystalline structure, boiling, sublimation, evaporation, dehydrogenation...

ASTM D5136-2019 High Purity Standard Specification for P-Xylene

abstraction This specification defines the requirements for paraxylene. The sample shall meet the following physical and chemical characteristics: minimum purity; Maximum m-xylene content; Maximum o-xylene content; Maximum sulfur content; Maximum toluene content; Maximum ethylbenzene content; Maximum non-aromatic content; To appear; Color (Pt/Co ratio); Distillation range; And maximum pressure. This summary is a brief overview of the reference standards. It is for reference only and is not an official part of the standard; Reference is required to the full text of the standard...