ASTM F2013-2016 Standardtestmethode zur Bestimmung von Acetaldehydrückständen in Polymeren aus Polyethylenterephthalatflaschen unter Verwendung eines automatischen statischen Headspace-Probenahmegeräts und eines Kapillargaschromatographen mit Flammenionisationsdetektor

ASTM F2013-10 (2016) Standard Test Method for Determination of acetaldehyde Residues in polyethylene terephthalate Bottle Polymers Using an Automatic Static Headspace Sampling Device and Capillary Gas Chromatograph with a Flame Ionization Detector is especially used as a quality control tool for molding or synthesis operations.

Bedeutung und Verwendung

5.1 This test method is especially used as a quality control tool for molding or synthesis operations. Acetaldehyde is a volatile degradation product produced during PET melting processing. As a result, it is captured in the side wall of the molded product and slowly desorbed into the contents packaged therein. In some foods and beverages, AA can give off an undesirable taste, so it is important to understand its concentration in PET products used in food contact applications.

ASTM F2013-2016 Standardtestmethode zur Bestimmung von Acetaldehydrückständen in Polymeren aus Polyethylenterephthalatflaschen unter Verwendung eines automatischen statischen Headspace-Probenahmegeräts und eines Kapillargaschromatographen mit Flammenionisationsdetektor

5.2 Desorption conditions at 150°C for 60 minutes should ensure that no measurable AA is produced in the sample during desorption.

Schritt 1: Umfang

1.1 This test method covers gas chromatography for the determination of ppm residual acetaldehyde (AA) in polyethylene terephthalate (HAUSTIER) homopolymers and copolymers used in beverage bottle production. This includes sample types for amorphous and solid particle samples and billet samples, as opposed to bottling tests (test method D4509), which require 24 hours of desorption into the top space of the bottle at 23°C before concentration. Headspace was quantified by a similar GC method.

1.2 In SI-Einheiten ausgedrückte Werte gelten als Standardwerte. This standard does not include other units of measurement.

1.3 Diese Norm soll nicht alle mit ihrer Verwendung verbundenen Sicherheitsbedenken berücksichtigen. Es liegt in der Verantwortung des Anwenders dieser Norm, vor der Verwendung geeignete Sicherheits- und Gesundheitsmaßnahmen festzulegen und die Anwendbarkeit behördlicher Beschränkungen zu bestimmen.

ASTM F2013-2016 Standardtestmethode zur Bestimmung von Acetaldehydrückständen in Polymeren aus Polyethylenterephthalatflaschen unter Verwendung eines automatischen statischen Headspace-Probenahmegeräts und eines Kapillargaschromatographen mit Flammenionisationsdetektor

2. Siehe die Datei

ASTM-Standard

D4509 Test method for the determination of acetaldehyde content in the 24-hour gas (AIR) space in newly blown PET bottles

E691 Praxis der Durchführung von Ringversuchen zur Bestimmung der Genauigkeit von Testmethoden