Metode Uji Standar ASTM D6801-2015 untuk Mengukur Suhu Pemanasan Mandiri Maksimum Karya Seni dan Bahan Lainnya

Arti dan kegunaannya

5.1 Metode pengujian ini memberikan kecenderungan untuk mempercepat pembakaran spontan material, which can eventually lead to a fire. Suitable for liquids and pastes.

5.2 The spontaneous heating behavior of oil-based materials is affected by the availability of oxygen, the amount of desiccant present, the degree of polymerization of the oil, the surface area of the cellulosic material, the measures taken to prevent heat dissipation, and the amount of oil in contact with the cellulosic material. The degree of spontaneous heating is independent of the type of cellulosic material in contact with the oil-based material or whether the oil-immersed material is first air-dried. Small amounts of contaminants, seperti cat, quartz powder, dirt, or desiccant (Misalnya, materials that may be found on dirty, oil-soaked rags), can act as catalysts for this reaction.

Metode Uji Standar ASTM D6801-2015 untuk Mengukur Suhu Pemanasan Mandiri Maksimum Karya Seni dan Bahan Lainnya

Melangkah 1: Cakupan

1.1 The test method includes a small-scale laboratory procedure to determine the self-heating tendency of oil-based materials exposed to high temperatures in air in a controlled semi-adiabatic system.

1.2 This test method was developed to address the urgent need to identify oil-based materials that may need to be labeled with a tendency to self-heating. Research based on this test method could allow the development of practices to identify such oil-based materials.

1.3 Nilai yang dinyatakan dalam satuan SI dianggap sebagai nilai standar. Nilai yang diberikan dalam tanda kurung hanya untuk referensi.

1.4 Standar ini tidak dimaksudkan untuk mengatasi semua masalah keselamatan, jika ada, terkait dengan penggunaannya. Pengguna standar ini bertanggung jawab untuk menetapkan praktik keselamatan dan kesehatan yang sesuai dan menentukan penerapan pembatasan peraturan sebelum digunakan.. Refer to Appendix X1 for specific safety issues related to the treatment of solvent-impregnated rags.

Bagikan postingan ini