Metodo di prova standard ASTM C1501-2019 per la valutazione della solidità del colore dei sigillanti strutturali degli edifici mediante procedure di invecchiamento accelerato di laboratorio

Significato e uso
5.1 This test method is designed to induce color changes in sealants and their component pigments related to the conditions of end use, including the effects of sunlight, moisture and heat. The exposures used in this test method are not intended to simulate color changes in sealants caused by local weathering phenomena, such as atmospheric pollution, biological attack, and saline exposure.

5.2 Quando si esegue l'esposizione in apparecchiature che utilizzano sorgenti luminose da laboratorio, it is important to consider how the manual test conditions will reproduce the performance variations and failure modes associated with the final use environment of the sealant under test. Information on the use and interpretation of accelerated exposure test data is provided in Practice G151.

5.3 When this test method is used as part of the specification, the exact procedure, condizioni di prova, test duration and evaluation techniques need to be specified. Due to the different spectral power distribution of the light sources (fluorescent ultraviolet and xenon arc), the results obtained between the two procedures may differ. Sealants should not be compared to each other based on results obtained in different types of equipment.

5.4 These devices are well matched to ultraviolet solar radiation. Tuttavia, for sealants that are sensitive to long wavelength ultraviolet and visible solar radiation, the absence of such radiation in fluorescent ultraviolet devices will distort the color stability ranking compared to external environmental exposure.

Nota 1: For a complete cautionary guide on laboratory ageing of non-metallic materials, see Practice G151.

Metodo di prova standard ASTM C1501-2019 per la valutazione della solidità del colore dei sigillanti strutturali degli edifici mediante procedure di invecchiamento accelerato di laboratorio

Raggio
1.1 This test method describes laboratory accelerated aging procedures for the determination of color stability of building construction sealants using fluorescent ultraviolet or xenon arc test devices.

1.2 The color stability rankings provided by these two programs may not be consistent.

1.3 I valori espressi in unità SI sono considerati standard. I valori indicati tra parentesi sono solo di riferimento.

1.4 There is no equivalent ISO standard for this test method.

1.5 Questo standard non è destinato ad affrontare tutti i problemi di sicurezza, se presente, legati al suo utilizzo. È responsabilità degli utenti di questo standard stabilire una sicurezza adeguata, pratiche sanitarie e ambientali e per determinare l'applicabilità delle restrizioni normative prima dell'uso.

1.6 Questo standard internazionale si basa su principi di standardizzazione riconosciuti a livello internazionale stabiliti nella Decisione sui principi per lo sviluppo di standard internazionali, Linee guida e raccomandazioni emesse dal Comitato sugli ostacoli tecnici al commercio dell'Organizzazione mondiale del commercio.

Condividi questo post