H1600 Portable dual channel isothermal amplification fluorescence detector
Product Introduction:

H1600 isothermal amplification fluorescence detection system is a portable isothermal amplification fluorescence detection instrument developed by Boheng Company. This product adopts dual-channel dual-8-hole module design, which can realize multi-purpose, as well as embedded 7-inch high-definition TFT color touch screen, WIN10 operating system, with its own analysis software, can complete quantitative analysis and print report without computer. It uses MARLOW customized Parstick module, high sensitivity photodetector and side scanning technology to ensure superior performance and stable detection results.

H1600 Portable dual channel isothermal amplification fluorescence detector
Application

This product can be used for real-time detection of pasture, forest farm, breeding farm and water source, rapid diagnosis of disaster, epidemic prevention and control, animal disease, food safety inspection and quarantine, as well as scientific research in biological laboratory.

H1600 Portable dual channel isothermal amplification fluorescence detector
Features of the instrument

1) Dual-channel dual-module design, free collocations experiment, can realize the independent operation of 2 different programs;

2) Small size, light weight, easy to carry;

3). With software analysis function, qualitative/quantitative analysis can be carried out;

4). 7-inch capacitive touch screen, Win10 operating system, simple operation, easy to start experiments;

5). Built-in 20G Flash memory, which can save up to 40,000 experimental data;

6) Optional printer, no need to connect to the computer directly print experimental results;

7) Using side scanning technology, the detection distance is close, the fluorescence acquisition signal is stable;

8). Dark-box reaction tank to avoid background noise;

9) Adopt the same acquisition optical path to improve repeatability;

10). LED light source, energy saving and environmental protection, long service life, maintenance-free;

11). Unique suction type electromagnetic lock cover technology;

12). The front soft shutdown button can prevent the accidental file or data loss caused by hard shutdown;

13). Constant current control circuit, smooth power output, prolong Peltier life, improve temperature control accuracy;

14). With over current, over temperature, power down data self-recovery and other protection functions, to ensure the safe operation of the experiment;

15). Forward and back out air duct design, can be placed side by side, saving laboratory space;

16). Can support lithium battery power supply, especially suitable for quick inspection and field inspection.
H1600 Portable dual channel isothermal amplification fluorescence detector
Technical parameters

Model number of productsH1601H1602
Volume of sample16×0.2ml (2×8 well, double module)
Applicable consumables0.2ml thin wall transparent single tube,0.2ml thin wall transparent eight tube
System of reaction15-100μl
Temperature control technologyAmerican MARLOW semiconductor refrigerator, more than 1 million cycles
Temperature control range0-100 ° C (resolution: 0.1 ° C)
Maximum rate of rise and fall6ºC/s
Temperature control accuracy±0.1 ºC
Homogeneity of temperature±0.25 ºC
Accuracy of temperature±0.25 ºC
Hot cover temperature range30-115 ° C (adjustable, default 105 ° C)
Temperature control modeBlock mode, Tube mode (automatic control according to the reaction volume)
Fluorescence excitation light wavelength460-550nm
Fluorescence detection wavelengthF1:520-540nmF1:520-540nm  F2:540-580nm
Suitable for fluorescent dyesF1:FAM/SYBR GreenF1:FAM/SYBR Green I

F2: HEX/VIC/JOE/TET

Excitation light sourceHigh brightness LED, long service life, no maintenance
Detector/detectorHigh sensitivity photoelectric sensor
Range of dynamics1-1010 Copies
Sensitivity of detectionSingle-copy genes can be detected
Software analysis functionQualitative/quantitative analysis
Data export formatexcel,csv,txt
Print outYou can print reports directly (USB thermal printer is optional)
Method of control7 inch color touch screen control, can also be connected to the computer control
Mode of interfaceWIFI/usb
Volume of volume300x267x198mm(L x W x H)
Weight8 KG
Operating voltage220VAC, 50Hz
PowerDC15V 255W

H1600 Portable dual channel isothermal amplification fluorescence detector Product Introduction: H1600 isothermal amplification fluorescence detection system is a portable isothermal amplification fluorescence detection instrument developed by Boheng Company. This product adopts dual-channel dual-8-hole module design, which can realize multi-purpose, as well as embedded 7-inch high-definition TFT color touch screen, WIN10 operating system, with its own analysis software, can complete quantitative analysis and print report without computer. It uses MARLOW customized Parstick module, high sensitivity photodetector and side scanning technology to ensure superior performance and stable detection results. H1600 Portable dual channel isothermal amplification fluorescence detector Application This product can be used for real-time detection of pasture, forest farm, breeding farm and water source, rapid diagnosis of disaster, epidemic prevention and control, animal disease, food safety inspection and quarantine, as well as scientific research in biological laboratory. H1600 Portable dual channel isothermal amplification fluorescence detector Features of the instrument 1) Dual-channel dual-module design, free collocations experiment, can realize the independent operation of 2 different programs; 2) Small size, light weight, easy to carry; 3). With software analysis function, qualitative/quantitative analysis can be carried out; 4). 7-inch capacitive touch screen, Win10 operating system, simple operation, easy to start experiments; 5). Built-in 20G Flash memory, which can save up to 40,000 experimental data; 6) Optional printer, no need to connect to the computer directly print experimental results; 7) Using side scanning technology, the detection distance is close, the fluorescence acquisition signal is stable; 8). Dark-box reaction tank to avoid background noise; 9) Adopt the same acquisition optical path to improve repeatability; 10). LED light source, energy saving and environmental protection, long service life, maintenance-free; 11). Unique suction type electromagnetic lock cover technology; 12). The front soft shutdown button can prevent the accidental file or data loss caused by hard shutdown; 13). Constant current control circuit, smooth power output, prolong Peltier life, improve temperature control accuracy; 14). With over current, over temperature, power down data self-recovery and other protection functions, to ensure the safe operation of the experiment; 15). Forward and back out air duct design, can be placed side by side, saving laboratory space; 16). Can support lithium battery power supply, especially suitable for quick inspection and field inspection. H1600 Portable dual channel isothermal amplification fluorescence detector Technical parameters Model number of products H1601 H1602 Volume of sample 16×0.2ml (2×8 well, double module) Applicable consumables 0.2ml thin wall transparent single tube,0.2ml thin wall transparent eight tube System of reaction 15-100μl Temperature control technology American MARLOW semiconductor refrigerator, more than 1 million cycles Temperature control range 0-100 ° C (resolution: 0.1 ° C) Maximum rate of rise and fall 6ºC/s Temperature control accuracy ±0.1 ºC Homogeneity of temperature ±0.25 ºC Accuracy of temperature ±0.25 ºC Hot cover temperature range 30-115 ° C (adjustable, default 105 ° C) Temperature control mode Block mode, Tube mode (automatic control according to the reaction volume) Fluorescence excitation light wavelength 460-550nm Fluorescence detection wavelength F1:520-540nm F1:520-540nm  F2:540-580nm Suitable for fluorescent dyes F1:FAM/SYBR Green F1:FAM/SYBR Green I F2: HEX/VIC/JOE/TET Excitation light source High brightness LED, long service life, no maintenance Detector/detector High sensitivity photoelectric sensor Range of dynamics 1-1010 Copies Sensitivity of detection Single-copy genes can be detected Software analysis function Qualitative/quantitative analysis Data export format excel,csv,txt Print out You can print reports directly (USB thermal printer is optional) Method of control 7 inch color touch screen control, can also be connected to the computer control Mode of interface WIFI/usb Volume of volume 300x267x198mm(L x W x H) Weight 8 KG Operating voltage 220VAC, 50Hz Power DC15V 255W