ASTM D4261-18 Standard Practice for Surface Cleaning of Concrete Blocks for Coating

Meaning and use 4.1 Surface cleaning shall be applied to the preparation of masonry surfaces of concrete units for coating for light service, spatter and spill of water and chemical solutions, radiation exposure, decontamination and repeated rinsing with alkaline cleaners. ASTM D4261-18 Standard Practice for Surface Cleaning of Concrete Blocks for Coating Step 1: Scope 1.1 This practice includes surface cleaning of the concrete block unit prior to application of paint to remove dust, dirt, mortar spatter, oil and grease. Procedures include vacuum cleaning,...

ASTM D4262-18 Standard Test Method for Surface pH of Chemically Cleaned or Etched Concrete

Meaning and use 3.1 Chemical cleaning and etching are used to prepare coated concrete. 3.2 Residual chemicals that are not removed by water flushing may adversely affect the properties and adhesion of coatings applied to concrete surfaces. The purpose of this test method is to determine that residual chemicals have been removed by measuring the acidity or alkalinity of the final rinsed surface. ASTM D4262-18 Standard Test Method for Surface pH of Chemically Cleaned or Etched Concrete Step 1: Scope 1.1 This test method includes...

ASTM D4263-18 Standard Test Method for the Determination of Moisture in Concrete by the Plastic Sheet Method

Meaning and use 2.1 Capillary moisture in concrete may be detrimental to the performance of some coating systems that cannot withstand moisture on or within surface boundaries. 2.2 Use this test method before coating concrete. ASTM D4263-18 Standard Test Method for the Determination of Moisture in Concrete by the Plastic Sheet Method Step 1: Scope 1.1 This test method is used to show the presence of capillary water in concrete. 1.2 Values in inches to pounds shall be considered as standard values. The values given in...

ASTM D4263-18 Standard Test Method for the Determination of Moisture in Concrete by the Plastic Sheet Method

Meaning and use 2.1 Capillary moisture in concrete may be detrimental to the performance of some coating systems that cannot withstand moisture on or within surface boundaries. 2.2 Use this test method before coating concrete. ASTM D4263-18 Standard Test Method for the Determination of Moisture in Concrete by the Plastic Sheet Method Step 1: Scope 1.1 This test method is used to show the presence of capillary water in concrete. 1.2 Values in inches to pounds shall be considered as standard values. The values given in...

ASTM D4285-18 Standard Test Method for Indicating Oil or Water in Compressed Air

Meaning and use 2.1 The compressed air needs to be cleaned to prevent contamination of the coating material and the surface on which the coating is prepared. This test method is a visual inspection technique used to determine oil or water in compressed air. Other types of contamination may require additional analytical techniques to detect. ASTM D4285-18 Standard Test Method for Indicating Oil or Water in Compressed Air Step 1: Scope 1.1 This test method is used to determine the presence of oil or...

ASTM D4285-18 Standard Test Method for Indicating Oil or Water in Compressed Air

Meaning and Use 2.1 Clean compressed air is required to prevent contamination of the coating material and the surface prepared for coating. The test method is a visual inspection technique used to determine oil or water in compressed air. Other types of contamination may require additional analytical techniques for detection. ASTM D4285-18 Standard Test Method for Indicating Oil or Water in Compressed Air Scope 1.1 This test method is used to determine the presence of oil or water in compressed air used for sandblasting,...

ASTM D4286-15 Standard Practice for Determining the Qualification of Coating Contractors for Nuclear Power Generation Facilities

This practice provides a standard guide and procedural approach to assist utility owners, architects, engineers, construction personnel, and other selection agencies in determining the overall qualifications of paint contractors to perform painting work on major containment and other safety-related facilities. Hydroelectric power plant. The qualification criteria and requirements relate to the basic basic competence of the contractor to perform nuclear coating work. The assessment procedures included here are designed to fit into the detailed final qualification process. Changes in practices...

ASTM D5367-16 “Standard practice for the Evaluation of Coatings Applied to Surfaces is treated with inhibitors to prevent flash rusting of steel upon water or water/abrasive sandblasting.

Meaning and Use 3.1 Water spray cleaning (SSPC-TR2 / NACE 6G 198; SSPC-SP 5 (WAB)/NACE WAB-1; SSPC-SP 10 (WAB)/NACE WAB-2; SSPC-SP 6 (WAB)/NACE WAB-3; SSPC-SP 14 (WAB)/NACE WAB-8); SSPC-SP 7 (WAB)/NACE WAB-4 or not, (SSPC-SP WJ-1 / NACE WJ-1; SSPC-SP WJ-2 / NACE WJ-2; SSPC-SP WJ-3 / NACE WJ- 3; SSPC-SP WJ-4 / NACE WJ-4) abrasive, which can cause flash rust under certain environmental conditions. Inhibitors are used to prevent flash rust during drying and before coating. The inhibitor or the...